Configuration Options
- Threaded and flanged process connections by drawing
- Stem profile and material by service conditions
- Sensor entry and bore dimensions matched to the probe installation
Temperature Sensors
A thermowell is a closed-end fitting that separates a thermocouple or RTD from the process fluid. Specify the vessel or pipe connection, the desired insertion length, and the sensor dimensions on the same drawing. Include the process conditions needed to review the material and mechanical design.

Configuration
The final construction depends on your drawing and operating conditions.
Use a section view of the installed assembly. Mark the process connection reference face, tip position in the fluid, and available clearance to remove the sensor.
| Drawing input | What to specify |
|---|---|
| Process connection | For a threaded fit, give the thread form and sealing details. For a flange, give its standard, size, facing, rating and gasket interface. |
| Insertion and stem | Show the installed reference face and the tip location relative to the nozzle, pipe wall or vessel internals. Provide the stem outline and any diameter limits. |
| Probe fit | Give the sensor diameter, installed length, seating or spring travel, sensor connection and the access needed to withdraw it. |
| Process and flow | Provide normal and peak temperature and pressure, fluid composition, line size and normal and maximum flow. Include any required mechanical or wake frequency evaluation criteria. |
Typical applications include pipeline or vessel temperature measurement with a removable thermocouple or RTD in a compatible thermowell.
Include your technical requirements, target quantity and any supporting drawings.