Temperature Sensors

Custom Thermowells

A thermowell is a closed-end fitting that separates a thermocouple or RTD from the process fluid. Specify the vessel or pipe connection, the desired insertion length, and the sensor dimensions on the same drawing. Include the process conditions needed to review the material and mechanical design.

Illustration of flanged and threaded metal thermowells with closed process ends
Illustrative configuration

Configuration

Specify Your Requirements

The final construction depends on your drawing and operating conditions.

Configuration Options

  • Threaded and flanged process connections by drawing
  • Stem profile and material by service conditions
  • Sensor entry and bore dimensions matched to the probe installation

Include in Your RFQ

  • Process connection standard, thread or flange dimensions, sealing interface and installed reference face
  • Insertion length from the process connection, stem outline and clearance in the pipe or vessel
  • Sensor diameter, installed length, bore depth, internal clearance and sensor connection
  • Fluid composition, temperature, pressure, and flow conditions for mechanical review

Match the Thermowell to the Process and Probe

Use a section view of the installed assembly. Mark the process connection reference face, tip position in the fluid, and available clearance to remove the sensor.

Match the Thermowell to the Process and Probe
Drawing inputWhat to specify
Process connectionFor a threaded fit, give the thread form and sealing details. For a flange, give its standard, size, facing, rating and gasket interface.
Insertion and stemShow the installed reference face and the tip location relative to the nozzle, pipe wall or vessel internals. Provide the stem outline and any diameter limits.
Probe fitGive the sensor diameter, installed length, seating or spring travel, sensor connection and the access needed to withdraw it.
Process and flowProvide normal and peak temperature and pressure, fluid composition, line size and normal and maximum flow. Include any required mechanical or wake frequency evaluation criteria.

Typical Applications

Typical applications include pipeline or vessel temperature measurement with a removable thermocouple or RTD in a compatible thermowell.

Ordering Questions

How do I measure thermowell insertion length?
Identify the installed process connection reference on the drawing and measure from that face to the thermowell tip. Include the wall or nozzle length so the depth into the process can be determined.
What dimensions keep the sensor fitted to the thermowell?
Specify the bore diameter and usable depth, probe diameter and insertion length, and the connection at the top. Show the intended seating position and include spring travel when the probe uses a spring-loaded fitting.
What data is needed for flow-induced loading review?
Provide the pipe and nozzle dimensions, installed stem profile and fluid properties, including density and viscosity. Include normal and maximum flow, process pressure and temperature, and any applicable standard or evaluation requirement.

Selection Guides

Request this configuration

Include your technical requirements, target quantity and any supporting drawings.

Request a Quote