Configuration Options
- Threaded or straight probe body by mounting drawing
- Nominal resistance and curve by instrument specification
- Cable, connector and probe sealing reviewed against the installation
Temperature Sensors
An NTC thermistor probe uses a sensing element whose electrical resistance decreases as temperature rises. For OEM and replacement inquiries, match the full resistance–temperature curve to the controller input, then share the probe mount, operating range and cable drawing.

Configuration
The final construction depends on your drawing and operating conditions.
For a replacement, start with the controller data and original probe drawing. A nominal resistance alone does not identify the full sensor curve.
| Selection input | What to provide |
|---|---|
| Resistance curve | State R25, tolerance and the required resistance table. If using a beta value, supply the temperature pair used to define it. |
| Threaded mounting | Give the thread standard, pitch and sealing feature. Measure the distance from the installed seating face to the sensing tip. |
| Straight probe mounting | Give the sheath diameter, usable depth and contact or insertion arrangement. Include the exposure at the cable transition. |
| Controller and cable | Confirm a resistance-measuring input for the NTC probe. A DS18B20 probe uses a digital interface. Share the controller input circuit, pinout and lead details. |
Typical inquiries include threaded or sealed probes for machinery and appliances with a specified NTC input.
Include your technical requirements, target quantity and any supporting drawings.