Tubular & Immersion

Inline Process Gas Heaters

An inline process gas heater transfers heat to gas flowing through a chamber. Select power from gas composition, mass flow and the required temperature rise. Review the chamber and element limits at the lowest operating flow as well as normal duty.

Illustration of a cylindrical inline process gas heater with flanged ports and a terminal enclosure
Illustrative configuration

Configuration

Specify Your Requirements

The final construction depends on your drawing and operating conditions.

Configuration Options

  • Heating zones and surface loading by gas flow and duty
  • Gas connections and chamber materials by project drawing
  • Temperature monitoring and flow permissive interfaces by control specification

Include in Your RFQ

  • Gas composition, moisture or contaminants and minimum, normal and maximum mass flow
  • Inlet and target outlet temperatures, allowable sheath temperature and warm-up duty
  • Operating and design pressure, allowable pressure drop, connection sizes and installation orientation
  • Voltage, phase, temperature limits, shutdown and applicable project documentation

Define the Gas, Flow Range and Mechanical Interfaces

Send the process data sheet and piping drawing. State the reference conditions for any standard or normal volumetric flow figures.

Define the Gas, Flow Range and Mechanical Interfaces
Selection inputWhat to provide
Heat duty and minimum flowProvide the gas mixture, the full flow range and the required inlet and outlet conditions. Include the lowest expected flow during startup or turndown.
Pressure and connectionsGive operating and design pressure, allowable pressure drop and nozzle orientation. Include material and documentation requirements.
Limits and controlIdentify sensor locations, required flow permissives, shutdown behavior, enclosure conditions and alarm interfaces.

Typical Applications

Typical inquiries include nonflammable gas conditioning and equipment heating with documented flow, pressure and temperature requirements.

Ordering Questions

Why does minimum gas flow matter when sizing an inline heater?
Lower flow can reduce cooling at the element surface. Evaluate the selected power, allowable sheath temperature and control or shutdown requirements at the lowest operating flow.
Which gas flow units should I provide?
Mass flow is useful for sizing. If flow is specified by volume, give the units and the temperature and absolute pressure used to define it.

Selection Guides

Request this configuration

Include your technical requirements, target quantity and any supporting drawings.

Request a Quote