Configuration Options
- Straight, U-shaped or multi-bend tube profiles by drawing
- Plain or finned construction by air path and heater envelope
- Mounting plates, brackets and terminal orientation to suit the equipment
Tubular & Immersion
An industrial oven heating element is a metal-sheathed resistance heater shaped to fit a heating zone in an oven or dryer. Send the mounting and tube profile drawing with the zone power and operating temperature. Include minimum airflow for forced convection or the spacing to the load for a radiant arrangement.

Configuration
The final construction depends on your drawing and operating conditions.
Use the oven wall or mounting plate as the reference for the installed tube dimensions. Show the space to install or withdraw the element and any nearby sheet metal or airflow baffles.
| Drawing detail | What to provide |
|---|---|
| Tube profile and supports | Show bend centerlines, active length, cold ends, mounting hole centers and support points. Include space for expansion along the hot span. |
| Forced convection zone | Give the minimum and normal airflow across the element, air direction, inlet and target temperatures, and any airflow baffles. |
| Radiant arrangement | Show the heated target, distance to the element and nearby shields or reflectors. Provide the required heating cycle. |
| Electrical layout | Identify supply voltage and phase, the power of each zone, terminal locations and cold-end length at the wall. |
Custom elements are considered for industrial batch ovens, drying chambers and conveyor ovens. Provide an equipment drawing or an existing part reference for a replacement.
Include your technical requirements, target quantity and any supporting drawings.