Configuration Options
- Titanium grade and wetted materials reviewed by chemical compatibility
- Immersed tube profile and support or mounting by tank drawing
- Heated span, electrical load and terminal arrangement by operating conditions
Tubular & Immersion
A titanium immersion heater transfers heat to a liquid through a titanium sheath. The required grade and other wetted materials depend on the bath chemistry, temperature and installation. Send the full bath specification and the tank drawing so the material, surface loading and mounting can be reviewed together.

Configuration
The final construction depends on your drawing and operating conditions.
Send the bath specification and a section view of the tank. Mark the wetted joints and supports, heated length and lowest liquid level during operation.
| Design input | What to provide |
|---|---|
| Chemical compatibility | List bath constituents and concentrations, operating temperatures and the cleaning process. Specify the titanium grade and other metal or seal materials that contact the liquid. |
| Fit, support and clearance | Show the mount, insertion depth, available clearance, supports and the path for withdrawing the element. Include the lowest operating liquid level. |
| Surface loading and power | Provide working volume, starting and target temperatures, heat-up time, minimum agitation or flow, and the supply and power requirements. |
Typical inquiries include compatible chemical process tanks, rinsing baths and industrial liquid heating assemblies specified for a titanium sheath.
Include your technical requirements, target quantity and any supporting drawings.