Temperature Sensors

Flanged Thermowells

A flanged thermowell bolts to a compatible vessel or piping nozzle and houses a removable thermocouple or RTD inside its closed-end stem. Send the mating flange and nozzle drawing, and specify the required probe fit and process conditions.

Illustration of a stainless flanged thermowell with a bolted mounting flange, closed stem and open instrument bore
Illustrative configuration

Configuration

Specify Your Requirements

The final construction depends on your drawing and operating conditions.

Configuration Options

  • Mating flange size, bolt pattern and facing by specification
  • Stem profile and insertion dimensions by nozzle and duty
  • Instrument connection and internal bore by probe drawing

Include in Your RFQ

  • Flange standard, nominal size, class or rating designation, facing and mating nozzle drawing
  • Insertion length from the installed reference face, stem profile, bore dimensions and clearance
  • Process fluid, normal and peak temperature and pressure, and normal and maximum flow
  • Instrument connection, probe seating, material requirements and documentation required for review

Match the Flange, Nozzle and Flow Conditions

Show the mating face, nozzle length and tip location in section. Include the mechanical evaluation requirements for the specified process.

Match the Flange, Nozzle and Flow Conditions
Review itemInclude in your inquiry
Flange interfaceIdentify the flange standard, nominal size, class, facing, bolt pattern and gasket requirements. Provide the mating nozzle drawing.
Stem and probe fitShow insertion from the specified reference face, nozzle clearance, outer stem profile, usable bore and sensor seat. Include space for probe withdrawal.
Process and mechanical reviewGive temperature, pressure, fluid properties and flow range. Include requirements for mechanical or wake-frequency evaluation and documentation.

Typical Applications

Typical inquiries include probe assemblies fitted to flanged nozzles in process piping and vessels.

Ordering Questions

What flange information is needed to quote a flanged thermowell?
Provide the mating flange standard, size, class, facing and bolt pattern with a section drawing showing the nozzle and intended tip position.
What process data is needed for a wake-frequency review?
Supply line size, installed stem profile, fluid density and viscosity, normal and maximum flow, temperature and pressure, and the project evaluation criteria.

Selection Guides

Request this configuration

Include your technical requirements, target quantity and any supporting drawings.

Request a Quote