Temperature Sensors

Flanged RTD Probes

A flanged RTD probe uses a flange to locate a platinum resistance sensor in the equipment. Match the flange, seating reference and insertion length on the installed drawing. Confirm the Pt100 or Pt1000 curve and the wire configuration required by the instrument.

Illustration of a stainless steel RTD probe with a round mounting flange and coiled lead cable
Illustrative configuration

Configuration

Specify Your Requirements

The final construction depends on your drawing and operating conditions.

Configuration Options

  • Flange outside dimensions, thickness and bolt pattern by drawing
  • Fixed insertion or adjustable mounting reviewed for the installation
  • Pt100 or Pt1000 element, sheath and lead termination by specification

Include in Your RFQ

  • Flange standard or custom drawing, facing, bolt circle and sealing interface
  • Sheath material and diameter, insertion length from the installed face, and clearance to withdraw the probe
  • Process medium, operating temperature, flow and pressure where applicable
  • Pt100 or Pt1000 curve, tolerance, wire count, lead length and termination

Match the Flange, Installed Depth and RTD Input

Provide an installed section drawing that shows the mating flange, sensor tip and cable or connection head clearance.

Match the Flange, Installed Depth and RTD Input
Specification detailWhat to provide
Flange and mounting faceList flange dimensions, hole pattern and seating or gasket details. Give any specified pressure rating when the flange forms a process boundary.
Insertion and thermowell fitMeasure from the installed reference face to the tip. For a thermowell installation, include the usable bore depth, diameter and probe seating details.
Resistance input and leadsConfirm the platinum curve, including Pt100 or Pt1000, the wire count, tolerance and how lead wires connect to the instrument.

Typical Applications

Typical inquiries include flanged RTD assemblies for process equipment, ducts, vessels and compatible thermowells.

Ordering Questions

Which dimensions are needed for a flanged RTD replacement?
Send the flange diameter, thickness, bolt pattern and sealing interface, plus the probe diameter and installed depth from the seating face. Include the original sensor and wiring specifications.
How should I specify an adjustable flange?
Show the allowable insertion range and fastening detail and describe the medium, temperature and pressure. Specify any sealing or pressure-boundary requirements separately.

Selection Guides

Request this configuration

Include your technical requirements, target quantity and any supporting drawings.

Request a Quote