A miniature sheathed thermocouple measures temperature at a defined point with a junction enclosed in a small-diameter probe. Set the diameter and insertion length from the equipment drawing. Review the sheath and junction together for the process medium, mechanical support and required response.

Illustration of a slim miniature sheathed thermocouple with a closed metal probe tip and flat-pin plug
Illustrative configuration

Configuration

Specify Your Requirements

The final construction depends on your drawing and operating conditions.

Configuration Options

  • Small-diameter sheath and transition reviewed for the available probe envelope
  • Thermocouple type and junction construction matched to the instrument and duty
  • Lead length, insulation and miniature plug or other termination by drawing

Include in Your RFQ

  • Allowable sheath diameter, overall and insertion lengths and junction position
  • Thermocouple type, grounded or ungrounded junction requirement and electrical isolation
  • Process temperature, medium, support and installed response target
  • Sheath and transition materials, lead clearance and termination

Match the Small Sheath to the Measurement Point

Provide the section view of the mounting location and mark the sensing tip. Include the required support and the maximum size of the lead transition.

Match the Small Sheath to the Measurement Point
Selection detailWhat to provide
Sheath envelopeGive the outside diameter limit, usable depth, mounting method and any bends, supports or seal requirements.
Junction and responseState the junction position, electrical isolation requirement and response under the actual contact or flow conditions.
Probe materials and leadsGive the medium, working temperature and routing dimensions. Include the temperature where the sheath joins the lead.
Exposed-bead configurationFor a test that calls for an exposed bead, provide the wire size, bead position and support arrangement.

Typical Applications

Typical inquiries include compact test fixtures, small tooling bores and equipment with limited space around the designated measurement point.

Ordering Questions

Does reducing the sheath diameter always give the required response?
Diameter influences response along with the junction, sheath material, insertion and heat transfer at the measurement point. Specify how response will be checked under installed conditions.
What determines the junction construction?
Share the instrument input, isolation requirement, response target and process conditions. These details guide the choice of a grounded or ungrounded junction in the specified sheath.