What is a thermocouple?
A thermocouple is a temperature sensor made from two different conductors joined at a sensing junction. The two conductors produce a small voltage that depends on the sensing and reference temperatures. An instrument converts this voltage to temperature using the reference function for the thermocouple type.
How does a thermocouple work?
The Seebeck effect produces a voltage along a conductor when its ends are at different temperatures. Two dissimilar conductors develop different voltages. Joining them at the sensing end allows the instrument to measure the difference at the reference end. The alloy pair determines how much the voltage changes with temperature.
What is a reference junction?
The reference junction is where the thermocouple conductors transition to the input circuit, often at the instrument terminals. Its temperature can differ from the sensing tip and can change as the enclosure warms up. Cold-junction compensation uses the measured reference temperature to correct the voltage before applying the temperature conversion.
How much voltage does a thermocouple produce?
Thermocouple signals are typically measured in millivolts. For example, the NIST ITS-90 reference table gives about 4.096 mV for a Type K junction at 100 °C with a 0 °C reference. If the reference is instead at 25 °C, the measured voltage is about 3.096 mV. The instrument compensates for that reference temperature and uses the Type K reference function to recover the sensing temperature.
What changes when the junction is built into a probe?
A probe adds mechanical protection, mounting and a wiring connection around the sensing junction. Those choices affect where the probe measures, how fast it responds and what environments it can tolerate.
| Part of the assembly | What it affects |
|---|---|
| Measuring junction | The effective sensing location, electrical isolation and thermal response. |
| Sheath or protection tube | Resistance to the process environment and the rate of heat transfer to the junction. |
| Mount and insertion length | Probe position in a vessel, duct or tool. |
| Extension wire and connector | Polarity and compatibility with the selected type and instrument. |
What are thermocouples used for?
Industrial thermocouples measure temperatures in furnaces, heated tools, process vessels and ducts. For an OEM replacement, match the type configured at the instrument and the installed sensing position. Share the working atmosphere and temperatures together with the drawing, because the same alloy type can be built into probes with different mounting and working limits.