Configuration Options
- PTFE, titanium or quartz sheaths reviewed for the specified chemistry
- Over-the-side or other specified mount by tank drawing
- Heated span, supports and terminal position by installed conditions
Tubular & Immersion
A plating tank heater transfers heat directly to an electroplating or surface-treatment bath. Send the bath formulation and operating temperatures with a tank section drawing. The bath and cleaning conditions determine the wetted materials. The tank lining, fixtures and lowest operating level determine where the heated section can fit.

Configuration
The final construction depends on your drawing and operating conditions.
Show the heater in its operating position with the lowest liquid level, tank lining, racks and perimeter clearance marked.
| Configuration | Include in your inquiry |
|---|---|
| PTFE-sheathed element | Give the complete bath chemistry and cleaning cycle to review the fluoropolymer, seals and supports. Include agitation and any deposits. |
| Titanium-sheathed element | Specify the bath formulation, temperature and any required titanium grade. Identify the materials of all wetted hardware. |
| Quartz-sheathed element | Provide the full bath and cleaning chemistry, thermal cycle and clearances to moving fixtures. |
| Over-the-side mounting | Show the tank rim, heated span below the lowest liquid level, clearances to lining and racks, and room to remove the assembly. |
Typical inquiries include electroplating, surface treatment and associated process baths with specified chemistry and temperature control.
Include your technical requirements, target quantity and any supporting drawings.