Temperature Controls

Thermocouple Signal Calibrators

A thermocouple signal calibrator can simulate a selected thermocouple input for a controller or transmitter. For measurement, specify the required millivolt or thermocouple read mode as a separate function. Include supported types, temperature or signal range, accuracy and cold-junction compensation requirements.

Illustration of a portable thermocouple signal calibrator with a display, connection sockets and adapter lead
Illustrative configuration

Configuration

Specify Your Requirements

The final construction depends on your drawing and operating conditions.

Configuration Options

  • Source and measurement functions by test requirements
  • Thermocouple types, signal range and connection by equipment specification
  • Accuracy and calibration documentation reviewed against acceptance criteria

Include in Your RFQ

  • Test purpose, supported thermocouple types and required source and measure modes
  • Millivolt or temperature range, resolution, required accuracy and cold-junction compensation method
  • Connector and lead configuration, receiving equipment and operating environment
  • Calibration documentation, test points, uncertainty and traceability requirements if specified

Specify Source, Measurement and Calibration Requirements

Send the test plan or instrument input specification. Identify which functions are needed and how each result will be verified.

Specify Source, Measurement and Calibration Requirements
Selection detailInclude in your inquiry
Signal sourceGive the required thermocouple types, setpoints or millivolt outputs, and the controller or transmitter input and connector.
Measurement and compensationSpecify the read mode and input range, accuracy and reference junction conditions. Include the required compensation method.
Calibration and evidenceState the acceptance criteria, test points and any required uncertainty, traceability or documentation for the supplied instrument.

Typical Applications

Typical inquiries include industrial maintenance, instrument checks and OEM verification of compatible thermocouple inputs.

Ordering Questions

What is the difference between source and measure modes?
Source mode provides the specified simulated signal to an input under test. Measure mode reads an applied signal. Identify the types, ranges and accuracy needed for each mode.
What is needed to check a complete thermocouple probe?
For a complete probe test, specify a suitable temperature source and reference measurement, test points and acceptance criteria. Signal simulation is used when checking the receiving instrument input.