Temperature Sensors

Thermocouple Vacuum Feedthroughs

A thermocouple feedthrough carries measurement leads through a chamber wall at a specified sealed interface. Send the chamber flange drawing and the required vacuum and temperature conditions, then identify each thermocouple pair and its pin assignments.

Illustration of a round vacuum flange with four isolated thermocouple feedthrough pins
Illustrative configuration

Configuration

Specify Your Requirements

The final construction depends on your drawing and operating conditions.

Configuration Options

  • Mating flange, seal interface and dimensions by drawing
  • Thermocouple pairs and contact materials reviewed for the circuit
  • Terminal positions and pin orientation by wiring layout

Include in Your RFQ

  • Chamber flange standard, dimensions, sealing face and space on both sides
  • Required vacuum range, leak-rate acceptance criteria and temperature or bakeout conditions
  • Thermocouple type, pair count, conductor or contact requirements and isolation
  • Pinout, polarity, terminal style and quantity

Specify the Vacuum Interface, Pins and Circuit Mapping

Show the mating flange and distinguish the two sides of the chamber on the wiring drawing.

Specify the Vacuum Interface, Pins and Circuit Mapping
Selection detailWhat to provide
Flange and seal conditionsGive the mating standard, bolt arrangement and sealing face. State the required vacuum and leak-rate acceptance conditions.
Temperature and clearanceInclude service and bakeout temperatures, available clearance on each side and the intended cable exit.
Contact materials and polarityIdentify the type and every conductor pair, approved materials, isolation and pin positions as viewed from both sides.

Typical Applications

Typical inquiries include thermocouple wiring for vacuum furnaces and chambers with an established flange and specified sealing requirements.

Ordering Questions

Can an RTD use the same feedthrough as a thermocouple?
Review the feedthrough pin materials, conductor count, insulation, current and temperature ratings and connector wiring. An RTD circuit needs the specified number of conductors and lead arrangement. Confirm the proposed feedthrough with the chamber and instrument drawings.
Which details identify a replacement thermocouple feedthrough?
Provide the original flange drawing, pin layout and contact specification, with required leak-rate test conditions and temperatures.
How should I identify multiple thermocouple pairs?
Label each pair and its positive and negative contacts on both sides of the flange. Include the instrument input and conductor requirements for each channel.

Selection Guides

Request this configuration

Include your technical requirements, target quantity and any supporting drawings.

Request a Quote