Temperature Sensors

Thermocouple Extension & Compensating Wire

Thermocouple extension and compensating wire carry the sensor signal from the probe or connection head to an instrument. Select the cable designation for the thermocouple type and the temperature at each transition. Specify the wiring standard and routing conditions with the inquiry.

Illustration of coiled braided thermocouple extension wire with a yellow and red conductor pair
Illustrative configuration

Configuration

Specify Your Requirements

The final construction depends on your drawing and operating conditions.

Configuration Options

  • Extension or compensating grade matched to the thermocouple circuit
  • Conductor size, insulation, jacket and shielding by installation
  • Cut lengths and terminations by wiring drawing

Include in Your RFQ

  • Thermocouple type, instrument input and required cable designation
  • ANSI/ASTM, IEC or other specified wiring convention and polarity
  • Conductor size, cable length, insulation and shielding requirements
  • Temperature at both transitions, routing environment and connector or terminal details

Match the Cable Grade and Polarity

Use the probe and instrument documentation to identify compatible cable. Check the thermoelectric temperature interval for the selected cable grade and the separate temperature limits of its insulation and jacket.

Match the Cable Grade and Polarity
Selection detailWhat to specify
Extension wireExtension-grade conductors use the same nominal alloys as the corresponding thermocouple pair. Provide the cable designation and expected transition temperatures.
Compensating cableCompensating alloys reproduce the required thermoelectric behavior over a specified temperature interval. Confirm the approved grade for the sensor circuit.
Color code and polarityInclude the wiring standard and identify the positive and negative terminals at the head, connector and instrument.
Routing and terminationSpecify cable length, conductor size, shielding, flexing, ambient temperature and connector or stripped-end details.

Typical Applications

Used between thermocouple probes, connection heads, field panels and compatible instrument inputs in industrial equipment.

Ordering Questions

What is the difference between thermocouple extension wire and compensating cable?
Extension wire uses conductors of the same nominal alloys as the thermocouple pair. Compensating cable uses different alloys to match the required output over a specified temperature interval. Check the designation and transition temperatures for the circuit.
Which color code should I specify for Type K extension wire?
Specify the standard used by the assembly. Type K positive and negative conductors are yellow and red under US ANSI/ASTM conventions, and green and white under IEC 60584-3. Check cable and terminal markings before connecting.

Selection Guides

Request this configuration

Include your technical requirements, target quantity and any supporting drawings.

Request a Quote