Temperature Sensors

Dual Element Thermocouples

A dual element thermocouple houses two sensing elements in one probe assembly. It can provide readings to a controller and a separate monitor through two identified pairs. Show both junction locations, the installation dimensions and the instrument inputs on the drawing.

Illustration of a single sheathed dual element probe with two separate braided leads and connectors
Illustrative configuration

Configuration

Specify Your Requirements

The final construction depends on your drawing and operating conditions.

Configuration Options

  • Dual sensing circuits in a sheathed assembly
  • Junction position and isolation by drawing
  • Separate lead and connector identification for each circuit

Include in Your RFQ

  • Instrument input and thermocouple type for each circuit
  • Junction locations, sheath diameter, material and installed insertion length
  • Grounding or electrical isolation requirements, working temperature and process atmosphere
  • Lead lengths, polarity, connector type and identification for each pair

Specify Both Circuits in a Duplex Thermocouple

Use one probe drawing to locate the sensing elements and show how each pair terminates. Include the instrument data for both inputs.

Specify Both Circuits in a Duplex Thermocouple
Drawing detailWhat to specify
Sheath and mountSheath material, diameter, available depth, seating reference and fittings.
Junctions and isolationJunction locations relative to the tip, response target and electrical isolation requirements between the elements and sheath.
Measurement inputsModel and thermocouple input for controller and monitor, normal and peak temperatures, and process exposure.
Lead pairsLead length, insulation, polarity and connector format for each input. Mark each pair on the wiring diagram.

Typical Applications

Applications to review include equipment that uses one probe location for temperature control and a separate temperature recording or monitoring input.

Ordering Questions

What is a dual element thermocouple?
It is a single probe with two thermocouple sensing elements and two identified lead pairs. The junctions, sheath and wiring must be specified for the installed assembly.
Can both circuits use separate instruments?
Specify the instrument model and sensor input for each circuit. Include the grounding arrangement, electrical isolation requirements and wiring diagram so the circuit layout can be reviewed.
Will both channels read the same temperature?
Junction position, heat flow, sensor tolerance and instrument error affect the measurements. Mark the intended locations and give the acceptable difference if the process specifies one.

Selection Guides

Request this configuration

Include your technical requirements, target quantity and any supporting drawings.

Request a Quote