Configuration Options
- Type K, S or R input reviewed for the application
- Sheath or ceramic protection tube by atmosphere and firing cycle
- Probe length, mounting collar and termination by drawing
Temperature Sensors
A kiln thermocouple measures temperature at a specified point in the firing chamber. To review a replacement or a new assembly, send the controller input, firing conditions and a wall section showing where the protected probe sits.

Configuration
The final construction depends on your drawing and operating conditions.
On the wall section, mark the seating face, inner hot face and intended sensing point. Indicate the probe orientation and space to withdraw the assembly for service.
| Drawing detail | What to provide |
|---|---|
| Controller input | Confirm the thermocouple type in the controller settings and the extension wire and terminal polarity used in the kiln. |
| Installed dimensions | Give port diameter, wall or refractory thickness, mounting details and the distance from the hot face to the sensing point. Mark clearance to shelves, heating elements and the load. |
| Protection and support | Specify the tube material if already required, outside diameter, orientation and supported length. Describe atmosphere, deposits and heating and cooling conditions. |
| Firing cycle and termination | Give the normal and peak cycle, time at temperature and conditions at the outer terminal or lead transition. Mark exit and service clearance. |
Typical inquiries include replacement temperature probes for pottery, ceramic and industrial kilns as well as assemblies for new kiln designs.
Include your technical requirements, target quantity and any supporting drawings.