Temperature Sensors

Type C Tungsten–Rhenium Thermocouples

Type C designates a tungsten–rhenium thermocouple with a tungsten–5% rhenium positive leg and a tungsten–26% rhenium negative leg. For a project inquiry, send the temperature profile, the atmosphere at the hot junction and the drawing for the furnace installation. The construction and availability are reviewed for those conditions.

Illustration of a Type C thermocouple element with a twin-bore ceramic insulator and exposed junction
Illustrative configuration

Configuration

Specify Your Requirements

The final construction depends on your drawing and operating conditions.

Configuration Options

  • Element, insulator and protection construction reviewed by application
  • Junction position and support layout by furnace drawing
  • Type C termination and compatible measuring circuit specified for the installation

Include in Your RFQ

  • Type C alloy designation and instrument input, continuous and peak temperatures, dwell time and cycle
  • Vacuum level or process gas composition through heat-up, operation and cool-down
  • Hot junction position, insulator or protection requirements, insertion and supported length
  • Mount and lead arrangement, transition temperature, and instrument or feedthrough specifications

Specify the Type C Furnace Atmosphere and Assembly

Provide the installation drawing and the gas or vacuum conditions at the measuring junction throughout the cycle. Confirm the reference characteristic required by your instrument.

Specify the Type C Furnace Atmosphere and Assembly
Application inputWhat to send
Atmosphere at the junctionVacuum level or gas composition, oxygen exposure during the cycle and any process deposits or material contact.
Temperature profileNormal and peak temperatures, time at peak, heating and cooling cycle, and the required instrument measurement span.
Protection and supportJunction location, tube or insulator requirements, support points, orientation and connection dimensions.
Instrumentation and wiringType C input or reference characteristic, cable or feedthrough details, polarity and the expected temperature at each transition.

Typical Applications

Typical inquiries include vacuum furnaces and compatible controlled-atmosphere equipment specified for Type C measurement.

Ordering Questions

What is a Type C thermocouple?
It is a thermocouple pairing tungsten–5% rhenium and tungsten–26% rhenium. Specify the Type C reference characteristic and compatible terminals and wiring for the instrument.
Why does the atmosphere matter for a Type C element?
Tungsten–rhenium alloys are susceptible to oxidation at elevated temperatures. Share the gas composition or vacuum level, including any exposure during heat-up or cool-down, to review the construction for the furnace.
What temperature limits should I specify in a Type C inquiry?
Give the required continuous and peak temperatures, duration and number of cycles, instrument measurement interval and temperature at the lead transition. The insulator, atmosphere, protection and termination each affect the assembly limits.

Selection Guides

Request this configuration

Include your technical requirements, target quantity and any supporting drawings.

Request a Quote